Advanced precision cooling solutions engineered for data centers, server rooms and mission-critical IT environments. MTT General Trading LLC supplies, installs and maintains CANATAL CRAH (Computer Room Air Handler) units across Abu Dhabi, Dubai and the UAE. Our solutions are designed to provide reliable chilled-water cooling, improved energy efficiency and precise environmental control for facilities operating around the clock. Whether you are developing a new data center, expanding an existing server room or upgrading your cooling infrastructure, our team can help identify the right precision cooling solution for your operational requirements.
A CRAH (Computer Room Air Handler) is an advanced precision cooling system designed to maintain stable temperature and humidity conditions in data centers, server rooms and other mission-critical IT environments.
Unlike conventional air conditioning systems, CRAH units use chilled water supplied by a central chiller plant. High-efficiency EC fans circulate warm return air across a chilled-water cooling coil, removing heat before delivering conditioned air back into the IT environment.
Since CRAH units do not contain an internal compressor, they offer reduced mechanical complexity, quieter operation and simplified maintenance. They are particularly suitable for medium and large data centers with centralized chilled-water infrastructure and continuous cooling requirements.
For data centers across the UAE, selecting the right CRAH system is essential for maintaining suitable operating conditions for servers, networking equipment and sensitive electronic infrastructure.
CRAH systems provide reliable cooling for a wide range of commercial, industrial and mission-critical applications.
01. Large and Hyperscale Data Centers
High-capacity precision cooling for large facilities operating thousands of servers and requiring continuous thermal management.
02. Colocation and Cloud Computing Facilities
Scalable cooling solutions supporting changing IT loads, high-density computing and redundant cooling configurations.
03. Enterprise Server Rooms
Precise temperature management for corporate IT infrastructure, centralized computing facilities and business-critical applications.
04. Telecommunications Facilities
Dependable cooling for network operations centers, communication rooms and telecommunications infrastructure.
05. Banking, Healthcare and Government
Environmental control for sensitive computing systems, essential data infrastructure and critical operations.
06. Oil and Gas Facilities
Precision cooling for industrial control rooms, monitoring systems and specialized electronic equipment.
07. Laboratories and UPS Rooms
Stable environmental conditions for testing equipment, electrical infrastructure and battery installations.
Energy efficiency is an important consideration for modern data centers, where cooling systems operate continuously. CRAH units combine chilled-water technology with advanced EC fan systems to deliver cooling according to actual room requirements.
Variable-Speed EC Fans: Adjust airflow according to cooling demand, helping reduce unnecessary fan energy consumption.
High-Performance Cooling Coils: Large-surface chilled-water coils support effective heat transfer and efficient cooling performance.
Modulating Water Valves: Regulate chilled-water flow according to the actual IT heat load.
Energy Optimization: Appropriate system configurations can help reduce cooling energy consumption and improve overall data center efficiency.
Servers and electronic equipment generate continuous heat that must be managed carefully. CRAH systems are designed for high sensible cooling loads, helping maintain stable environmental conditions.
Accurate Temperature Management: Maintains suitable operating conditions for sensitive servers and networking equipment.
High Sensible Cooling Performance: Focuses on removing heat generated by IT equipment.
Optional Humidification: Helps maintain suitable humidity conditions within critical environments.
Electric Reheat: Provides additional environmental control when required by the application.
Data centers require dependable cooling throughout the year. CRAH systems can incorporate redundancy and intelligent operating controls to support continuous operation.
N+1 and N+X Redundancy: Additional cooling capacity helps maintain availability when an individual unit becomes unavailable.
Automatic Lead-Lag Operation: Coordinates multiple units and rotates operating priorities to balance equipment usage.
Standby Operation: Additional units can provide backup cooling when required.
Dual Power Options: Optional configurations provide additional operational flexibility.
Water Leak Detection: Optional monitoring helps protect critical IT spaces and equipment.
Every data center has different structural and airflow requirements. CRAH units are available in different configurations to accommodate raised-floor installations, ducted applications and specialized cooling layouts.
Downflow Configuration: Suitable for raised-floor data centers where conditioned air is distributed beneath the floor.
Upflow Configuration: Suitable for ducted installations or direct room air distribution.
Fan-Wall Configuration: Designed for larger cooling applications requiring high-volume airflow.
Flexible Piping Connections: Different connection arrangements accommodate site-specific installation requirements.
Service Accessibility: Equipment configurations can support convenient inspection, servicing and maintenance.
Modern precision cooling equipment incorporates intelligent control systems that help operators monitor performance, manage operating conditions and identify potential issues.
Microprocessor Controllers: User-friendly controllers provide access to equipment settings and operating information.
Temperature Monitoring: Helps operators monitor room conditions and cooling performance.
Alarm Notifications: Provides system alerts and event history to support maintenance activities.
BMS and DCIM Integration: Modbus, BACnet and SNMP communication options support integration with Building Management Systems and Data Center Infrastructure Management platforms.
Multi-Unit Coordination: Coordinated operation helps manage multiple CRAH units within the same cooling environment.
Data center cooling equipment installed in the UAE must be selected with consideration for high outdoor temperatures, dust and coastal humidity. Appropriate filtration, coil protection and equipment configurations can help support reliable performance in demanding environments.
Dust Protection: Suitable filtration options help protect cooling equipment in dusty operating environments.
Coastal Protection: Optional protective coil coatings can be considered for installations exposed to coastal conditions.
Environment-Specific Selection: Equipment configuration should be selected according to actual site conditions.
Maintenance Support: Regular inspection and preventive maintenance help maintain system performance.
The following specifications provide a general overview of available CRAH system configurations. Final equipment selection depends on the manufacturer, cooling capacity and project requirements.
Cooling Medium
Chilled water supplied by a central chiller plant.
Cooling Capacity
Approximately 20 kW to 200 kW per unit, with larger fan-wall configurations potentially available.
Airflow Configuration
Downflow, upflow and fan-wall arrangements.
Fan Type
High-efficiency EC centrifugal fans with variable-speed operation.
Water Control
Two-way or three-way modulating valves.
Filtration
G4 standard, with optional higher-grade filtration.
Optional Features
Humidification, electric reheat, dual power supply and water leak detection.
Communication
Modbus RTU/TCP, BACnet and SNMP communication options.
Redundancy
N+1, N+X, automatic rotation and standby configurations.
Note: Specifications are indicative and subject to the selected CANATAL model and project requirements. Final selection should consider IT heat load, room dimensions, chilled-water temperatures and airflow requirements.
Both CRAH and CRAC systems are designed for precision cooling in data centers and server rooms. However, they use different cooling technologies and are suitable for different infrastructure requirements.
CRAH systems use chilled water supplied by a central chiller plant. They are generally suitable for medium and large data centers with existing centralized cooling infrastructure. They can provide efficient cooling at scale and support larger cooling loads.
CRAC systems use an integrated direct expansion refrigeration circuit with a compressor. They are often suitable for smaller server rooms and facilities without central chilled-water infrastructure.
Cooling Infrastructure: CRAH requires a chiller, pumps and chilled-water piping, whereas CRAC typically uses an outdoor condenser and refrigerant circuit.
Typical Application: CRAH is commonly considered for medium and large data centers, while CRAC is suitable for small and medium server rooms.
System Selection: The right solution depends on project size, existing infrastructure, energy requirements and future expansion plans.
Explore our CRAC Units for Data Centers and Server Rooms to learn about alternative precision cooling solutions.
MTT General Trading LLC provides precision cooling equipment and technical support for data centers, server rooms and critical infrastructure projects throughout the UAE.
CANATAL Equipment Supply: Precision cooling equipment for commercial and mission-critical applications.
Site Assessment: Evaluation of cooling loads, room dimensions and infrastructure requirements.
Engineering Support: Assistance with equipment selection and cooling system configuration.
Installation and Commissioning: Professional installation, testing and operational checks.
Preventive Maintenance: Scheduled maintenance and Annual Maintenance Contracts (AMC).
Technical Assistance: Ongoing support to help maintain cooling system performance.
UAE-Wide Coverage: Support across Abu Dhabi, Dubai, Sharjah, Al Ain and other UAE locations.
Looking for reliable CRAH units for your data center or server room? MTT can help you identify a suitable chilled-water precision cooling solution based on your facility size, IT heat load, cooling requirements and future expansion plans.
Contact our team to discuss your project, request technical information or receive a quotation for CANATAL CRAH cooling systems.